Technical specifications

Technical data

Anode voltage 60–120 kV
Anode current 1–16 mA
Focal spot 0.5 mm, fixed anode
Image detector Flat panel
Image acquisition 200 / 360 degree rotation
Scan time 1–36 s
Typical reconstruction time 2–55 s

Maximum volume sizes

Volume size [mm]

Planmeca Viso™ G5

Maximum volume with a single scan:
Ø200 x 100

Maximum volume with multiple vertical scans:
Ø200 x 170

Planmeca Viso G5 maximum volume size

Planmeca Viso™ G7

Maximum volume with a single scan:
Ø300 x 190

Maximum volume with multiple vertical scans:
Ø300 x 300

Planmeca Viso G7 maximum volume size

Dental programs

Volume size [mm]

Planmeca Viso G5

Tooth
Min/max volume: Ø30 x 30 – Ø60 x 60
Default: Ø50 x 50
Voxel size: 75 μm*, 150 μm, 300 μm, 450 μm

Teeth
Min/max volume: Ø70 x 30 – Ø90 x 90
Default: Ø90 x 90
Voxel size: 150 μm, 300 μm, 450 μm

Jaw
Min/max volume: Ø100 x 30 – Ø200 x 100
Default: Ø140 x 100
Voxel size: 150 μm, 300 μm, 450 μm, 600 μm

Face
Min/max volume: Ø140 x 130 – Ø200 x 170
Default: Ø160 x 160
Voxel size: 200 μm, 300 μm, 450 μm, 600 μm

Planmeca Viso G7

Tooth
Min/max volume: Ø30 x 30 – Ø60 x 60
Default: Ø50 x 50
Voxel size: 75 μm*, 150 μm, 300 μm, 450 μm

Teeth
Min/max volume: Ø70 x 30 – Ø120 x 100
Default: Ø100 x 100
Voxel size: 150 μm, 300 μm, 450 μm

Jaw
Min/max volume: Ø130 x 30 – Ø170 x 170
Default: Ø140 x 100
Voxel size: 150 μm, 300 μm, 450 μm, 600 μm

Face
Min/max volume: Ø140 x 120 – Ø260 x 200
Default: Ø160 x 160
Voxel size: 150 μm, 300 μm, 450 μm, 600 μm

Skull
Min/max volume: Ø260 x 300 – Ø300 x 300
Default: Ø260 x 300
Voxel size: 300 μm, 450 μm, 600 μm

*Requires Endodontic imaging licence

ENT (Ear, Nose, Throat) programs

Volume size [mm]

Planmeca Viso G5

Nose
Min/max volume: Ø70 x 50 – 90 x 90
Default: Ø80 x 80
Voxel size: 200 μm, 300 μm, 450 μm, 600 μm

Sinus
Min/max volume: Ø100 x 100 – 200 x 1500
Default: Ø130 x 130
Voxel size: 300 μm, 450 μm, 600 μm

Middle ear
Min/max volume: Ø30 x 30 – 60 x 60
Default: Ø50 x 50
Voxel size: 75 μm*, 150 μm, 300 μm, 450 μm

Temporal bone
Min/max volume: Ø70 x 50 – 90 x 90
Default: Ø80 x 80
Voxel size: 150 μm, 300 μm, 450 μm

Airways
Min/max volume: Ø90 x 80 – 110 x 100
Default: Ø90 x 100
Voxel size: 150 μm, 300 μm, 450 μm

Vertebrae
Min/max volume: Ø90 x 80 – 110 x 100
Default: Ø90 x 100
Voxel size: 150 μm, 300 μm, 450 μm

Planmeca Viso G7

Nose
Min/max volume: Ø70 x 50 – 120 x 100
Default: Ø80 x 80
Voxel size: 150 μm, 300 μm, 450 μm

Sinus
Min/max volume: Ø100 x 100 – 160 x 160
Default: Ø130 x 130
Voxel size: 300 μm, 450 μm, 600 μm

Middle ear
Min/max volume: Ø30 x 30 – 60 x 60
Default: Ø50 x 50
Voxel size: 75 μm*, 150 μm, 300 μm, 450 μm

Temporal bone
Min/max volume: Ø70 x 50 – 120 x 100
Default: Ø80 x 80
Voxel size: 150 μm, 300 μm, 450 μm

Airways
Min/max volume: Ø80 x 80 – 100 x 140
Default: Ø90 x 100
Voxel size: 150 μm, 300 μm, 450 μm

Vertebrae
Min/max volume: Ø80 x 80 – 100 x 140
Default: Ø80 x 100
Voxel size: 150 μm, 300 μm, 450 μm

*Requires Endodontic imaging licence

Dimensions

3D imaging units dimensions

3D imaging units dimensions

Physical space requirements

Width 155 cm (61 in.)
Depth 152 cm (60 in.),
Height* 240 cm (95 in.)
Weight 165 kg (lbs 364 )

With cephalostat:
Width 216 cm (85 in.)
Depth 152 cm (60 in.)
Height*180 cm (95 in.)
Weight 180 kg (lbs 397)

*The maximum height of the unit can be adjusted for offices with limited ceiling space.

Example installation

Included in delivery

Planmeca 3D unit with 3D reconstruction server

Planmeca 3D unit with 3D reconstruction server

Minimum set up

Client workstation and database server

  • Planmeca Romexis 3D Explorer
  • Database server
  • Planmeca Romexis Image Database

The client workstation and database server can also be in separate computers.

Planmeca client workstation and database server

Additional equipment

Additional diagnostic workstations with different software configurations

Planmeca Romexis tools:

  • 3D Explorer
  • 3D Cross Sections module
  • 3D TMJ module
  • 3D Implant Planning module
  • DICOM module

The client workstation and database server can also be in separate computers.

Planmeca additional workstations with different software configurations